{"id":10103,"date":"2026-07-17T13:18:00","date_gmt":"2026-07-17T11:18:00","guid":{"rendered":"https:\/\/sentenso.info\/?page_id=10103"},"modified":"2026-07-17T12:58:42","modified_gmt":"2026-07-17T10:58:42","slug":"faq","status":"publish","type":"page","link":"https:\/\/sentenso.info\/en\/technologies\/x-ray-diffractometer\/x360j\/faq\/","title":{"rendered":"x360j | faq (en)"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"10103\" class=\"elementor elementor-10103 elementor-10097\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2ad11017 e-con-full e-flex e-con e-parent\" data-id=\"2ad11017\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2b8a4e3d elementor--h-position-center elementor--v-position-middle elementor-arrows-position-inside elementor-pagination-position-inside elementor-widget elementor-widget-slides\" data-id=\"2b8a4e3d\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;transition_speed&quot;:1000,&quot;autoplay_speed&quot;:4000,&quot;navigation&quot;:&quot;both&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;infinite&quot;:&quot;yes&quot;,&quot;transition&quot;:&quot;slide&quot;}\" data-widget_type=\"slides.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper\">\n\t\t\t\t\t<div class=\"elementor-slides-wrapper elementor-main-swiper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Slider\" dir=\"ltr\" data-animation=\"fadeInUp\">\n\t\t\t\t<div class=\"swiper-wrapper elementor-slides\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-repeater-item-50a3443 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"Banner-1_Eigensspannungen-1870px\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><h1 class=\"elementor-slide-heading\">Pulstec \u00b5-X360J<\/h1><h2 class=\"elementor-slide-description\">Mobile. Fast. User-friendly.<\/h2><a href=\"mailto:info@sentenso.de\" class=\"elementor-button elementor-slide-button elementor-size-sm\"><span style=\"font-size:20px; font-style:normal;\">   <i class=\"fa\" style=\"margin-right:12px;\">&#xf0e0;<\/i>   Angebot anfordern <\/span><\/a><\/div><\/div><\/div><div class=\"elementor-repeater-item-7058616 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"Banner-2_Eigensspannungen-1870px\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><h1 class=\"elementor-slide-heading\">Pulstec \u00b5-X360J<\/h1><h2 class=\"elementor-slide-description\">Innovative. Precise. Compact.<\/h2><a href=\"mailto:info@sentenso.de\" class=\"elementor-button elementor-slide-button elementor-size-sm\"><span style=\"font-size:20px; font-style:normal;\">   <i class=\"fa\" style=\"margin-right:12px;\">&#xf0e0;<\/i>   Angebot anfordern <\/span><\/a><\/div><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\" aria-label=\"Previous slide\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-left\"><\/i>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\" aria-label=\"Next slide\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-right\"><\/i>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-pagination\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f281eb4 e-flex e-con-boxed e-con e-parent\" data-id=\"f281eb4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3053a9 elementor-widget elementor-widget-html\" data-id=\"f3053a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<section  id=\"faq-mu-x360j-en\"\n  class=\"faq-section\"\n  aria-label=\"FAQ about the \u00b5-X360J X-ray diffractometer\"\n  style=\"max-width:850px;margin:0 auto;padding:2rem 0; scroll-margin-top: 215px;\">\n\n\n  <div style=\"display:flex;align-items:center;justify-content:space-between;gap:1rem;margin-bottom:1.5rem;\">\n    <h2 style=\"font-size:1.4rem;font-weight:600;line-height:1.3;margin:0;flex:1;\">\n      Questions and answers about the \u00b5-X360J\n    <\/h2>\n\n    <button id=\"rsToggleAllBtnEn\"\n      style=\"font-size:13px;font-weight:500;color:#185FA5;background:#E6F1FB;border:1px solid #B5D4F4;border-radius:20px;padding:6px 16px;cursor:pointer;white-space:nowrap;flex-shrink:0;\">\n      Expand all\n    <\/button>\n  <\/div>\n\n  <div id=\"rsFaqAccordionEn\" style=\"display:flex;flex-direction:column;gap:8px;\">\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        What is the \u00b5-X360J X-ray diffractometer?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The \u00b5-X360J is the latest generation of X-ray stress analyser \u2013 also usable mobile \u2013 for the fast and\n            reliable determination of residual stresses and retained austenite in metallic components.\n            By changing the tube, it can be used on a wide range of metals and alloys as well as ceramics.\n            It replaces the established \u00b5-X360s and sets new standards in precision, speed and ease of use.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        What are the advantages of the \u00b5-X360J compared to the \u00b5-X360s?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The \u00b5-X360J offers higher precision, shorter measurement times and significantly improved usability.\n            It also enables more stable and efficient measurement processes as well as extended automation\n            through the optional StressEasy software.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        What applications is the \u00b5-X360J suitable for?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The system is designed for residual stress and retained austenite determination in metallic components.\n            Typical applications include assessing material condition, fatigue strength and quality assurance in\n            manufacturing processes. It also provides indications of dislocation density, texture and coarse grain.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        Can the \u00b5-X360J be used in production environments?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            Yes, thanks to its easy positioning and short measurement times, the \u00b5-X360J is ideal for use\n            both in laboratories and directly in production.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        What is the role of the StressEasy software?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The optional StressEasy software enables extensive automation of measurement processes,\n            including stress mapping, batch measurements and integrated target value checks for production lines.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        Can measurements be fully automated?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            Yes, in combination with a six-axis robot, the system becomes highly automated.\n            Measurements can be performed sequentially without user intervention in a fully digitised workflow.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        What is stress mapping and how is it used?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            Stress mapping allows area-based analysis of residual stress states. In the \u00b5-X360J, mappings are\n            customisable and can be enhanced with oscillation movements at selected positions.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        How user-friendly is the system?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The \u00b5-X360J is designed for ease of use. Features such as automatic calibration and easy\n            component replacement significantly reduce user effort.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        How does the tube module replacement work?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The tube module can be easily replaced via a plug-in system after loosening two mounting screws.\n            The integrated collimator also allows flexible adjustment of the measurement spot size.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        What improvements does the detector offer?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            The larger detector allows for a greater measuring distance, improving accessibility and\n            enhancing the resolution of the measurement signal.\n          <\/p>\n        <\/div>\n      <\/div>\n    <\/div>\n\n    <!-- FAQ ITEM -->\n    <div class=\"rs-faq-item\">\n      <div class=\"rs-faq-summary\">\n        Your question is not listed?\n        <span class=\"rs-faq-icon\">\n          <svg viewBox=\"0 0 12 12\" width=\"12\" height=\"12\" fill=\"none\" stroke=\"#888\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\">\n            <polyline points=\"2,4 6,8 10,4\"\/>\n          <\/svg>\n        <\/span>\n      <\/div>\n      <div class=\"rs-faq-body\">\n        <div class=\"rs-faq-body-inner\">\n          <p>\n            Then simply get in touch. Together we will find the right solution for your requirements\n            around the \u00b5-X360J, residual stresses and retained austenite.\n          <\/p>\n\n          <div style=\"text-align:center; margin-top:60px; margin-bottom:40px;\">\n            <a\n              href=\"mailto:info@sentenso.de?subject=Enquiry%20about%20the%20%C2%B5-X360J\"\n              style=\"\n                display:inline-block;\n                padding:12px 24px;\n                background:#0080C6;\n                color:#fff;\n                text-decoration:none;\n                border-radius:6px;\n                font-weight:600;\n              \"\n            >\n              Send enquiry\n            <\/a>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\n  <\/div>\n<\/section>\n\n<style>\n.rs-faq-item{background:#fff;border:1px solid #e0dfd8;border-radius:12px;overflow:hidden;transition:border-color .2s,box-shadow .2s;}\n.rs-faq-item.open{border-color:#0080C6;box-shadow:0 2px 12px rgba(24,95,165,.08);}\n.rs-faq-summary{display:flex;align-items:center;justify-content:space-between;gap:12px;padding:15px 18px;cursor:pointer;font-size:15px;font-weight:500;color:#0080C6;user-select:none;}\n.rs-faq-summary:hover{background:#fafaf8;}\n.rs-faq-icon{flex-shrink:0;width:24px;height:24px;border-radius:50%;background:#f0efea;display:flex;align-items:center;justify-content:center;transition:background .2s;}\n.rs-faq-item.open .rs-faq-icon{background:#E6F1FB;}\n.rs-faq-item.open .rs-faq-icon svg{stroke:#185FA5;transform:rotate(180deg);}\n.rs-faq-icon svg{transition:transform .3s ease,stroke .2s;}\n.rs-faq-body{max-height:0;overflow:hidden;transition:max-height .35s cubic-bezier(.4,0,.2,1);}\n.rs-faq-item.open .rs-faq-body{max-height:400px;}\n.rs-faq-body-inner{padding:0 18px 18px;}\n.rs-faq-body p{font-size:14px;line-height:1.75;color:#555;border-left:2px solid #0080C6;padding-left:12px;margin:0;}\n<\/style>\n\n<!-- FAQ JSON-LD -->\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"inLanguage\": \"en\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the \u00b5-X360J X-ray diffractometer?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The \u00b5-X360J is the latest generation of X-ray stress analyser \u2013 also usable mobile \u2013 for the fast and reliable determination of residual stresses and retained austenite in metallic components. By changing the tube, it can be used on a wide range of metals and alloys as well as ceramics. It replaces the established \u00b5-X360s and sets new standards in precision, speed and ease of use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What are the advantages of the \u00b5-X360J compared to the \u00b5-X360s?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The \u00b5-X360J offers higher precision, shorter measurement times and significantly improved usability. It also enables more stable and efficient measurement processes as well as extended automation through the optional StressEasy software.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What applications is the \u00b5-X360J suitable for?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The system is designed for residual stress and retained austenite determination in metallic components. Typical applications include assessing material condition, fatigue strength and quality assurance in manufacturing processes. It also provides indications of dislocation density, texture and coarse grain.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the \u00b5-X360J be used in production environments?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, thanks to its easy positioning and short measurement times, the \u00b5-X360J is ideal for use both in laboratories and directly in production.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the role of the StressEasy software?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The optional StressEasy software enables extensive automation of measurement processes, including stress mapping, batch measurements and integrated target value checks for production lines.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can measurements be fully automated?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, in combination with a six-axis robot, the system becomes highly automated. Measurements can be performed sequentially without user intervention in a fully digitised workflow.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is stress mapping and how is it used?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Stress mapping allows area-based analysis of residual stress states. In the \u00b5-X360J, mappings are customisable and can be enhanced with oscillation movements at selected positions.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How user-friendly is the system?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The \u00b5-X360J is designed for ease of use. Features such as automatic calibration and easy component replacement significantly reduce user effort.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does the tube module replacement work?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The tube module can be easily replaced via a plug-in system after loosening two mounting screws. The integrated collimator also allows flexible adjustment of the measurement spot size.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What improvements does the detector offer?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The larger detector allows for a greater measuring distance, improving accessibility and enhancing the resolution of the measurement signal.\"\n      }\n    }\n  ]\n}\n<\/script>\n\n<script>\n(function(){\n\n  var items = document.querySelectorAll('#faq-mu-x360j-en .rs-faq-item');\n  var btn = document.getElementById('rsToggleAllBtnEn');\n  var allOpen = false;\n\n  items.forEach(function(item){\n\n    item.querySelector('.rs-faq-summary').addEventListener('click', function(){\n\n      var isOpen = item.classList.contains('open');\n\n      items.forEach(function(i){\n        i.classList.remove('open');\n      });\n\n      if(!isOpen){\n        item.classList.add('open');\n      }\n\n      updateBtn();\n\n    });\n\n  });\n\n  btn.addEventListener('click', function(){\n\n    allOpen = !allOpen;\n\n    items.forEach(function(i){\n      i.classList.toggle('open', allOpen);\n    });\n\n    btn.textContent = allOpen\n      ? 'Collapse all'\n      : 'Expand all';\n\n  });\n\n  function updateBtn(){\n\n    allOpen =\n      document.querySelectorAll('#faq-mu-x360j-en .rs-faq-item.open').length === items.length;\n\n    btn.textContent = allOpen\n      ? 'Collapse all'\n      : 'Expand all';\n  }\n\n})();\n<\/script>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Pulstec \u00b5-X360J Mobile. Fast. User-friendly. &#xf0e0; Angebot anfordern Pulstec \u00b5-X360J Innovative. Precise. Compact. &#xf0e0; Angebot anfordern Questions and answers about the \u00b5-X360J Expand all What is the \u00b5-X360J X-ray diffractometer? The \u00b5-X360J is the latest generation of X-ray stress analyser \u2013 also usable mobile \u2013 for the fast and reliable determination of residual stresses and [&hellip;]<\/p>\n","protected":false},"author":10,"featured_media":0,"parent":10338,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"site-sidebar-layout":"no-sidebar","site-content-layout":"page-builder","ast-site-content-layout":"full-width-container","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"disabled","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-10103","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/pages\/10103","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/comments?post=10103"}],"version-history":[{"count":7,"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/pages\/10103\/revisions"}],"predecessor-version":[{"id":10110,"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/pages\/10103\/revisions\/10110"}],"up":[{"embeddable":true,"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/pages\/10338"}],"wp:attachment":[{"href":"https:\/\/sentenso.info\/en\/wp-json\/wp\/v2\/media?parent=10103"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}